PACKAGING
5.
(The packaging requirements specified herein apply only for direct Government
acquisition)
For the extent of applicability of the packaging requirements of
referenced documents listed in section 2, see 6.7 )
General requirements.
5.1
5.1.1 Lumber and plywood. Unless otherwise specified (see 6.2), the
Cleanliness of the
preservative fluid shall be in accordance with MIL-H-6083
preservative fluid shall meet the following requirements:
(a) Particulate count:
Maximum number of
particles per
Particulate size
100 milliliters
(micrometers)
14,000
greater than 15
2,500
greater than 25
400
greater than 50
No particles over 500 micrometers, except fibers
are permitted. Fibers are defined as particles
with a length at least 10 times the diameter.
(b) Water content shall be not more than 0.05 percent by volume,
5 1.2 Navy fire-retardant requirements.
5.1.2.1 Lumber and plywood When specified (see 6.2), all lumber and
plywood including laminated veneer material used in shipping container construc-
tion members, blocking, bracing, and reinforcing shall be fire-retardant treated
material conforming to MIL-L-19140 as follows
Levels A and B - Type II - weather resistant.
Category 1 - general use
- Type I - non-weather resistant
Level C
Category 1 - general use
5.1.2.2 Fiberboard
When specified (see 6.2), fiberboard used in the
construction of class-domestic, non-weather resistant fiberboard and cleated
fiberboard boxes including interior packaging forms shall meet the flamespread and
the specific optic density requirements of PPP-F-320 amendments thereto
Preservation shall be level A or commercial, as specified
5.2 Preservation.
(see 6 2)
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business