5.6.2 Special marking, Preserved assemblies shall be tagged, and the
exterior shipping container marked or labeled with the following
"The interior of this item has been coated (or filled, as applicable) with
(list preservative, fluid brand or Military specification as applicable) on
(provide date of preservation)."
5.7 Technical manuals. Technical manuals which accompany shipments that are
packed level A or B shall be packaged in transparent, waterproof plastic bags,
minimum of 4 roils thickness. Closure shall be by heat sealing. Technical manuals
shall not be placed with any sealed flexible barrier material used to enclose the
i terns. Manuals, when shipped in bulk quantities, shall not be individually
wrapped, but shall be packed in accordance with the requirements of the applicable
manual specification or packed in containers conforming to the requirements for
level A, B, or C, as specified (see 5.3).
6
NOTES
(This section contains information of a general or explanatory nature that
may be helpful, but is not mandatory.)
6.1 Intended use. The actuators covered in this specification are intended
Actuators are suitable for use in systems
for use in ship hydraulic systems
using either petroleum-based, water-glycol, or triaryl phosphate ester hydraulic
fluids .
6.2 Acquisition requirements.
Acquisition documents must specify the
following:
Title, number, and date of this specification.
(a)
(b)
Classification of rotary actuators (see 1.2).
Category of rotary actuator required (see 1.2.1).
(c)
(d)
Those minor differences or variations of basic design which
characterize the rotary actuator as category 11 (see 1.2.1.2,
3 4 6, and 3 5,7).
(e)
All configuration and performance requirements for category III
actuators (see 1 2.1.3, 3.4 1, 3.4 3, 3.44, 3.4 6, 3.4 7, 3 5.6,
3.5.7, and 3.5.9).
(f)
Issue of DoDISS to be cited in the solicitation, and if required,
the specific issue of individual documents referenced (see 2 1 1
and 2.2).
When first article inspection is required (see 3.2).
(g)
When materials for extremely corrosive environment are required
(h)
(see 3.3.1).
(i)
Piston seal requirements for category II and III rotary actuators,
if other than specified (see 3.4.2 and 3.4,11).
Requirements for system and test fluids, if other than specified
(j)
(see 3 4.2, 3 5 11.1, and 4.5.1)
(k)
Shaft rotating angle requirements for category II and III rotary
actuators (see 3.4 5)
(1)
The minimum number of operating life cycles when greater than that
identified in the specification or applicable specification sheet
(see 3 4 6),
17
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business